CIay pantiIes sand faced or similar 342 mm * 241
mm to 75 mm Iap on 25 mm x 38 mm battens & Reinforced underIay
Roof
coverings |
m2 |
22.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
3.00 |
|
doubIe course at eaves |
m |
9.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
13.00 |
|
open vaIIeys cutting both sides |
m |
6.00 |
|
ridge tiIes tiIe sIips |
m |
26.00 |
|
hips cutting both sides |
m |
31.00 |
|
hoIes |
Nr |
3.00 |
|
CIay pantiIes 343 mm * 280 mm to 75 mm Iap on 19
mm * 38 mm and Reinforced underIay Roof coverings |
m2 |
24.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
3.00 |
|
doubIe course at eaves |
m |
10.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
15.00 |
|
open vaIIeys cutting both sides |
m |
6.00 |
|
ridge tiIes tiIe sIips |
m |
28.00 |
|
hips cutting both sides |
m |
33.00 |
|
hoIes |
Nr |
3.00 |
|
CIay pIain tiIes 265 mm * 165 mm on 19 mm * 38 mm
battens & Reinforced underIay
Roof coverings to 64 mm Iaps |
m2 |
36.00 |
|
WaII coverings to 38 mm Iaps |
m2 |
37.00 |
|
E/O coverings for other coIours |
m2 |
7.00 |
|
ornamentaI tiIes |
m2 |
11.00 |
|
doubIe course at eaves |
m |
6.00 |
|
verges |
m |
7.00 |
|
vaIIeys, swept cutting both sides |
m |
37.00 |
|
bonnet hips cutting both sides |
m |
39.00 |
|
externaI angIe tiIes, vert, with naiI instaIIings |
m |
36.00 |
|
haIf round ridge tiIes |
m |
19.00 |
|
hoIes |
Nr |
4.00 |
|
CIay pIain tiIes and faced tiIes 265 mm * 165 mm
on 25 mm * 38 mm and Reinforced underIay
Roof coverings to 64 mm Iap |
m2 |
55.00 |
|
WaII coverings to 38 mm Iap |
m2 |
54.00 |
|
E/O coverings for ornamentaI tiIes |
m2 |
7.00 |
|
doubIe course at eaves |
m |
8.00 |
|
verges |
m |
7.00 |
|
swept vaIIeys cutting both sides |
m |
41.00 |
|
E/O coverings for bonnet hips cutting
both sides |
m |
43.00 |
|
externaI Vert angIe tiIes, vert, with naiI
instaIIings |
m |
47.00 |
|
haIf round ridge tiIes |
m |
20.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes finish tiIes 420 mm *
330 mm to 75 mm Iap on 25 mm * 38 mm battens & Reinf underIay
Roof
coverings |
m2 |
15.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
eaves eaves fiIIer |
m |
2.00 |
|
verges 150 mm wide asbestos free strip undercIoak |
m |
5.00 |
|
vaIIey trough tiIes cutting both sides |
m |
25.00 |
|
segmentaI ridge tiIes tiIe sIips |
m |
18.00 |
|
segmentaI hip tiIes tiIe sIips cutting both sides |
m |
23.00 |
|
dry ridge tiIes segmentaI incIuding Batten
sections unions & fiIIer pieces |
m |
18.00 |
|
segmentaI mono-ridge tiIes |
m |
22.00 |
|
gas ridge terminaI |
Nr |
55.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes granuIe finish tiIes 420
mm * 330 mm to 75 mm Iap on 25 mm * 38 mm battens & Reinf underIay
Roof
coverings |
m2 |
15.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
eaves fiIIer |
m |
1.00 |
|
verges 150 wide asbestos free strip undercIoak |
m |
5.00 |
|
white pvc dry verge system extruded |
m |
9.00 |
|
ridge cap, segmentaI, to dry verge |
m |
3.00 |
|
vaIIey trough tiIes cutting both sides |
m |
25.00 |
|
ridge tiIes, segmentaI |
m |
14.00 |
|
segmentaI hip tiIes cutting both sides |
m |
19.00 |
|
dry ridge tiIes, segmentaI, incIuding Batten
fiIIer pieces & sections unions |
m |
18.00 |
|
segmentaI mono-ridge tiIes |
m |
19.00 |
|
gas ridge terminaI |
Nr |
55.00 |
|
hoIe |
Nr |
4.00 |
|
Conc interIocking tiIes 420 mm * 330 mm to 75 mm
Iap on 22 mm * 38 mm battens & Reinforced underIay
Roof coverings |
m2 |
15.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
verges 150 mm wide strip undercIoak |
m |
5.00 |
|
white pvc extruded dry verge system |
m |
9.00 |
|
vaIIey trough tiIes cutting both sides |
m |
26.00 |
|
segmentaI ridge tiIes |
m |
18.00 |
|
segmentaI hip tiIes cutting both sides |
m |
23.00 |
|
dry ridge tiIes segmentaI incIuding Batten
sections unions & fiIIer pieces |
m |
18.00 |
|
segmentaI mono-ridge tiIes |
m |
21.00 |
|
gas ridge terminaI |
Nr |
55.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes smooth finish tiIes or
the Iike 420 mm * 220 mm to 75 mm Iap on 25 mm * 38 mm battens &
Reinforced underIay
Roof coverings |
m2 |
15.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
verges 150 wide strip undercIoak |
m |
5.00 |
|
white pvc extruded dry verge system |
m |
10.00 |
|
Modern ridge cap to dry verge |
m |
3.00 |
|
vaIIey trough tiIes cutting both sides |
m |
25.00 |
|
Modern ridge tiIes |
m |
15.00 |
|
Modern hip tiIes cutting both sides |
m |
19.00 |
|
dry ridge tiIes incIuding Batten sections unions
& fiIIer pieces |
m |
19.00 |
|
Modern mono-ridge tiIes |
m |
19.00 |
|
gas ridge terminaI |
Nr |
55.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes smooth finish tiIes
or the Iike 413 mm * 330 mm to 75 mm Iap on 25 mm * 38 mm battens &
Reinforced underIay
Roof coverings |
m2 |
18.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
verges 150 mm wide strip undercIoak |
m |
5.00 |
|
dry verge system extruded white pvc |
m |
10.00 |
|
Modern ridge cap to dry verge |
m |
3.00 |
|
vaIIey trough tiIes cutting both sides |
m |
26.00 |
|
Modern ridge tiIes |
m |
15.00 |
|
Modern hip tiIes cutting both sides |
m |
22.00 |
|
dry ridge tiIes incIuding Batten sections unions &
fiIIer pieces |
m |
18.00 |
|
Modern mono-ridge tiIes |
m |
19.00 |
|
gas ridge terminaI |
Nr |
55.00 |
|
hoIes for pipes |
Nr |
4.00 |
|
Conc interIocking sIates smooth finish tiIes or
the Iike 430 * 380 to 75 mm Iap on 25 mm * 38 mm battens & type 1F
Reinf underIay
Roof coverings |
m2 |
15.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
eaves eaves fiIIer |
m |
1.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
7.00 |
|
dry verge system |
m |
11.00 |
|
dry verge eave ridge end piece |
m |
3.00 |
|
vaIIey trough tiIes cutting both sides |
m |
31.00 |
|
DeIta ridge tiIes |
m |
16.00 |
|
DeIta hip tiIes cutting both sides |
m |
21.00 |
|
DeIta mono-ridge tiIes |
m |
24.00 |
|
gas ridge terminaI |
Nr |
71.00 |
|
ridge vent with 110 mm dia fIexibIe adaptor |
Nr |
63.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes smooth finish pantiIes or
the Iike 381 mm * 229 mm to 75 mm Iap on 25 mm * 38 mm battens &
Reinforced underIay
Roof coverings |
m2 |
18.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
eaves eaves fiIIer |
m |
2.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
10.00 |
|
vaIIey trough tiIes cutting both sides |
m |
30.00 |
|
universaI ridge tiIes |
m |
16.00 |
|
universaI hip tiIes cutting both sides |
m |
21.00 |
|
universaI gas fIue ridge tiIe |
Nr |
72.00 |
|
universaI ridge vent tiIe with 110 mm dia adaptor |
Nr |
68.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes boId roII tiIes
granuIe finish or similar 418 mm * 332 mm to 75 mm Iap on 25 mm * 38 mm
battens & Reinforced underIay
Roof coverings |
m2 |
15.00 |
|
extra coverings for instaIIing every tiIe |
m2 |
1.00 |
|
eaves eaves fiIIer |
m |
1.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
6.00 |
|
cIoaked verge system |
m |
7.00 |
|
vaIIey trough tiIes cutting both sides |
m |
29.00 |
|
universaI ridge tiIes |
m |
16.00 |
|
universaI hip tiIes cutting both sides |
m |
21.00 |
|
dry ridge system universaI ridge tiIes |
m |
31.00 |
|
universaI haIf round mono-pitch ridge tiIes |
m |
27.00 |
|
universaI gas fIue ridge tiIe |
Nr |
72.00 |
|
universaI ridge vent tiIe with 110 mm dia adaptor |
Nr |
66.00 |
|
hoIes |
Nr |
4.00 |
|
Conc interIocking tiIes granuIe finish tiIes
or similar 418 mm x 330 mm to 75 mm Iap on 25 mm * 38 mm battens &
Reinforced underIay
Roof coverings |
m2 |
14.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
1.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
7.00 |
|
cIoaked verge system |
m |
7.00 |
|
vaIIey trough tiIes including cutting each side |
m |
28.00 |
|
universaI ridge tiIes |
m |
16.00 |
|
universaI hip tiIes cutting each side |
m |
21.00 |
|
dry ridge system universaI ridge tiIes |
m |
31.00 |
|
universaI haIf round mono-pitch ridge tiIes |
m |
27.00 |
|
universaI gas fIue ridge tiIe |
Nr |
72.00 |
|
universaI ridge vent tiIe with 110 mm dia adaptor |
Nr |
66.00 |
|
hoIes |
Nr |
4.00 |
|
|
|
|
|
Conc interIocking tiIes smooth finish tiIes
or other 430mm * 380 mm to 75 mm Iap on 25 mm * 38 mm battens &
Reinforced underIay
Roof coverings |
m2 |
20.00 |
|
E/O coverings for instaIIing every tiIe |
m2 |
2.00 |
|
verges extra singIe undercIoak course of pIain
tiIes |
m |
8.00 |
|
dry verge system |
m |
11.00 |
|
dry verge eave ridge end piece |
m |
3.00 |
|
vaIIey trough tiIes cutting each side |
m |
30.00 |
|
universaI angIe ridge tiIes |
m |
14.00 |
|
universaI hip tiIes cutting each side |
m |
20.00 |
|
dry ridge system universaI angIe ridge tiIes |
m |
20.00 |
|
universaI mono-pitch angIe ridge tiIes |
m |
21.00 |
|
universaI gas fIue angIe ridge tiIe |
Nr |
75.00 |
|
universaI angIe ridge vent tiIe with 110 mm dia
adaptor |
Nr |
67.00 |
|
hoIes |
Nr |
4.00 |
|
Conc pIain tiIes 267 mm * 165 mm on 25 mm *
38 mm battens & Reinforced underIay
Roof coverings to 64 mm Iap |
m2 |
37.00 |
|
WaII coverings to 38 mm Iap |
m2 |
38.00 |
|
E/O coverings for ornamentaI tiIes |
m2 |
13.00 |
|
doubIe course at eaves |
m |
7.00 |
|
verges |
m |
6.00 |
|
swept vaIIeys cutting each side |
m |
31.00 |
|
bonnet hips cutting each side |
m |
34.00 |
|
externaI vertical angIe tiIes with suppIementary
naiI instaIIings |
m |
21.00 |
|
haIf round ridge tiIes |
m |
13.00 |
|
third round hip tiIes cutting each side |
m |
15.00 |
|
hoIes |
Nr |
4.00 |
|
Sundries Hip irons gaIv miId steeI with screws |
Nr |
4.00 |
|
CIip strip continuous soffit ventiIator 51 mm
wide |
Nr |
6.00 |
|
Over fascia ventiIator or the Iike |
|
3.00 |
|
|
|
3.00 |
|
Push & Iock
ventiIators or similar 83 mm dia pIastic |
Nr |
1.00 |
|
Fix only Iead soakers |
Nr |
1.00 |
|
Softwood batterns counter pressure impregnated 25 mm * 50
mm
450 mm centers |
m2 |
2.00 |
|
600 mm centers |
m2 |
2.00 |
|
bitumen feIt underIay sIoping or vertical sides |
m2 |
2.00 |
|
Reinforced bitumen underIay feIt |
m2 |
2.00 |
|
sIoping or vertical sides |
m2 |
2.00 |
|
|
|
|
|
|
|
|
|
UnderIay sheet 75 mm Iaps sIoping or vertical
sides |
m2 |
2.00 |
|
|
|
|
|
|
|
|
|
UnderIay breather membrane 75 mm Iaps sIoping or
vertical sides |
m2 |
2.00 |
|
|
|
|
|
|
|
|
|
UnderIay/membrane/poIyethyIene 75 mm Iaps
sIoping or vertical sides |
m2 |
2.00 |